Phone:
400-168-1306
The TKD XO-5032UD series is an ultra-high-fundamental differential oscillator in a 5.0 × 3.2 mm package, engineered for the lowest phase noise in high-frequency timing. It is ideal for core networking, radar, satellite communications and high-end measurement systems.
| Technical Specifications | LVPECL | LVDS | HCSL | unit. | ||||||||||
| 3.3V | 2.5V | 3.3V | 2.5V | 3.3V | 2.5V | |||||||||
| Min. | Max. | Min. | Max. | Min. | Max. | Min. | Max. | Min. | Max. | Min. | Max. | |||
| Nominal Frequency | 100,125,156.25,212.5,312.5 | MHz | ||||||||||||
| Operating Voltage (VDD) | VDD-5% | VDD+5% | VDD-5% | VDD+5% | VDD-5% | VDD+5% | VDD-5% | VDD+5% | VDD-5% | VDD+5% | VDD-5% | VDD+5% | V | |
| Output Frequency | 100 | 500 | 10 | 250 | 10 | 250 | 10 | 250 | 25 | 175 | 25 | 175 | MHz | |
| Input current | 10MHz≤F0<160MHz | - | 75 | - | 75 | - | 50 | - | 50 | - | - | - | - | mA |
| 25MHz≤F0≤175MHz | - | - | - | - | - | - | - | - | - | 50 | - | 50 | mA | |
| 160MHz≤F0<250MHz | - | 100 | - | 100 | - | 50 | - | 50 | - | - | - | - | mA | |
| Output level | Output high level | 2.275 | - | 1.475 | - | - | 1.6 | - | 1.6 | 0.6 | - | 0.58 | - | V |
| Output low level | - | 1.68 | - | 0.88 | 0.9 | - | 0.9 | - | - | 0.15 | - | 0.15 | V | |
| Transition Time: Rise/Fall Time | - | 0.5 | - | 0.5 | - | 0.5 | - | 0.5 | - | 0.5 | - | 0.5 | nSec | |
| Startup time | - | 10 | - | 10 | - | 10 | - | 10 | - | 10 | - | 10 | mSec | |
| Three-state(connect to pin2 or pin1) | Enable (High level or floating) | 2.31 | - | 1.75 | - | 2.31 | - | 1.75 | - | 0.7VDD | - | 0.7VDD | - | V |
| Disable (Low level or grounded) | - | 0.99 | - | 0.75 | - | 0.99 | - | 0.75 | - | 0.3VDD | - | 0.3VDD | V | |
| Aging rate (@25℃, first year) | - | ±3 | - | ±3 | - | ±3 | - | ±3 | - | ±3 | - | ±3 | ppm | |
| Storage temperature | -55 | 125 | -55 | 125 | -55 | 125 | -55 | 125 | -55 | 125 | -55 | 125 | ℃ | |
| Phase Noise @156.25MHz | -125 | -125 | -120 | -120 | -dBc/Hz | |||||||||
* Nominal frequency refers to the designed frequency of the crystal and does not indicate inventory availability.
+Transition time is measured within a 20% to 80% change in supply voltage.